Local Meshing Controls

Local Mesh Controls can be applied to either a Geometry Selection or a Named Selection. These are available only when the mesh branch is highlighted. Available controls include :

-Method Control

-Sizing Control

-Contact Sizing Control

-Refinement Control

-Mapped Face Meshing (EMAG and cyclic, not covered)

-Inflation Control

-Pinch Control

-Gap Tool (EMAG only, not covered)

Local Meshing Controls : Method (continued)

-Method Control : Provides the user with options as to how solid bodies are meshed: (Valid only for bodies).

-Automatic (default):

.Body will be swept if possible. Otherwise, the “Patch Conforming” mesher under “Tetrahedrons” is used.

-Continued

Curvature and Proximity Refinement = Yes:

-Define by: maximum element size or approximate number of elements.

-Defeaturing Tolerance (yes): adds tolerance controls to defeature edges.

-Curvature and Proximity:automatically refines mesh based on curvature and proximity of features.

-Num Cells across Gap–Specifies the number of cells desired in narrow gaps. Refinement is limited by the Min Size Limit.

-Span Angle–Mesh will subdivide in curved regions till the individual elements span the specified angle. Limited by Min Size Limit.

-Hex Dominant : Creates a free hex dominant mesh. Useful for meshing bodies that cannot be swept. Recommended for meshing bodies with large interior volumes. (only available with ANSYS Structural licenses and above)

-The hex-dominant meshing algorithm creates a quad-dominant surface mesh first, then pyramid and tetrahedral elements are filled in as needed.

.“Control Messages” will appear to warn user if volume may not be suitable for hex-dominant meshing

Sweep :

-Sweep-mesh (hex and possible wedge) elements, otherwise tetrahedra.

-RMB on mesh branch to “Show Sweepable Bodies”.

-Type : Number of Divisions or Element Size in the sweep direction.

-Sweep Bias Type : Bias spacing in sweep direction.

Src/Trg Selection :

-Automatic, manual source or manual source and target.

-Automatic Thin Model–One hex or wedge through the thickness. Can choose between Solid -Shell (SOLSH190) element and a Solid element (Solid185)

-Manual Thin Model–Allows user to pick a source face.

Local Meshing Controls

Sizing:

-“Element Size” specifies average element edge length or number of divisions (choices depend on geometry selection).

-“Soft” control may be overridden by other mesh controls. “Hard” may not.

-Mesh biasing is available.

-Available options above depend on which entities are scoped:

Sphere of Influence sizing, see next page.