Introduction to CFX -Solver Settings

Initialization
Solver Control
Output Control

Solver Manager
Note: This chapter considers solver settings for steady-state simulations. Settings specific to transient simulation are discussed in a later chapter.
Iterative solution procedures require that all solution variables are assigned initial values before calculating a solution
A good initial guess can reduce the solution time
In some cases a poor initial guess may cause the solver to fail during the first few iterations
The initial values can be set in 3 ways:
1.Solver automatically calculates the initial values
2.Initial values are entered by the user
3.Initial values are obtained from a previous solution
Initial values can be set on a per-domain basis or globally for all domains
Insert Global Initialisation from the toolbar or by right-clicking on Flow Analysis 1


Edit each Domain to set initial values on a per-domain basis
When both are defined the domain settings take precedence
Solid domain must have initial conditions set on a per-domain basis